Artificial intelligence

Scientific journal

ISSN 2710-1673

ONLINE: ISSN 2710-1681

Select your language


Computer model of control of a flat solar collector with a thermosifon circulation

Kalimoldaev M.1, Amirgaliyev Y.2, Kunelbyaev M.3, Merembaev T.4, Sundetov T.5
1 Institute of Information and Computing Technologies of the Ministry of Education and Science of the Republic of Kazakhstan
2 Institute of Information and Computing Technologies of the Ministry of Education and Science of the Republic of Kazakhstan
3 Institute of Information and Computing Technologies of the Ministry of Education and Science of the Republic of Kazakhstan
4 Institute of Information and Computing Technologies of the Ministry of Education and Science of the Republic of Kazakhstan
5 Institute of Information and Computing Technologies of the Ministry of Education and Science of the Republic of Kazakhstan

Full text (PDF)

UDC: 62-67; 62-69
Publication Language: Russian
Stuc. intelekt. 2019; 24(1-2):75-86

Abstract: This paper discusses the possibility of creating a digital platform based on Mojo v3 for monitoring the operation of a dual-circuit solar collector. In the proposed system, measurements are made from 6 digital sensors (DS18B20 Dallas), 16 wires are used. Using Dallas sensors and the appropriate software, you can monitor the temperature level and the amount of heat. The use of 6 digital sensors significantly increases the efficiency of control over the system and increases the speed of data processing. The possibilities of configuring sensors for the platform Mojo v3, as well as the control circuit of the solar collector are considered.

Keywords: solar energy, flat solar collector, platform Mojo v3, controller

References:

  1. Duffie, J.A., Beckman, W.A. (1991). SolarEngineering of Thermal Processes. John Wiley andSons: New York.
  2. Samanci, A., Berber, A. (2011, February 18).Experimental investigation of single-phase andtwophase closed thermosyphon solar water heatersystems. Scientific Research and Essays, Vol. 6(4),pp. 688-693.
  3. Islam, M.A., Khan, M.A.R., Sarkar, M.A.R. (2005).Performance of a Two-Phase Solar Collector inWater Heating Journal of Energy & Environment 4,Technical Note, pp. 117–123.
  4. Chuawittayawuth, K.,Kumar, S. (2002).Experimental investigation of temperature and flowdistribution in a thermosyphon solar water heatingsystem. Renewable Energy 26 (2002), pp. 431–448.
  5. Taherian, H., Rezania, A., Sadeghi, S., Ganji, D.D.(2011). Experimental validation of dynamicsimulation of the flat plate collector in a closedthermosyphon solar water heater. EnergyConversion and Management 52, pp. 301–307.
  6. Zerrouki, A., Boumedien, A., Bouhadef, K. (2002).The natural circulation solar water heater modelwith linear temperature distribution. RenewableEnergy 26, pp. 549–559.
  7. Luna Abreu, S., Colle, S. (2004). An experimentalstudy of two-phase closed thermosyphons forcompact solar domestic hot-water system, SolarEnergy 76, pp. 141–145.
  8. Hobbi, A., Siddiqui, K. (2009). Experimental studyon the effect of heat transfer enhancement devices inflat-plate solar collectors. International Journal ofHeat and Mass Transfer 52, 4650–4658.
  9. Ogueke, N.V., Anyanwu, E.E., Ekechukwu, O.V.(2009). A review of solar water heating systems.Journal of Renewable and Sustainable Energy 1,043106.
  10. Dr. Mohammed, A.A. (2011). Heat Transfer andPressure Drop Characteristics of Turbulent Flow ina Tube Fitted With Conical Ring and Twisted TapeInserts. Engg. & Tech. Journal, vol. 29, no. 2.pp. 34–39
  11. De Marchi Neto, I., Padilha, A. (2008). RefrigeratorCOP with thermal storage. Appl. Therm.Eng. 29(1), 2358–2364.
  12. Souza, L.M.P. (2011). Levantamento deCoeficientes de Desempenho de Armazenador Te ́rmico Associado a Refrigerador Dome ́sticoModificado. Universidade Estadual Paulista-Ju ́liode Mesquita Filho, Campus de Bauru, Mestrado.
  13. Taheri, H. (2014). PhD’s Thesis. A.: KarlsruheInstitut fur Technologie (KIT), Karlsruhe,Germany.
  14. Rosen, M.A., Kumar, R. (2011). Performance of aphotovoltaic/thermal solar air heater: effect ofvertical fins on a double pass system. Int. J. EnergyEnviron. Eng. 2(4), 1–4.
  15. Sugathan, A., Kirthyvijay, G.J., Thomson, J.(2013). Application of Arduino based platform forwearable health monitoring system. In: Presented atthe 1st International Conference on ConditionAssessment Techniques in Electrical Systems.
  16. Faizan, V., Galib, M., Khan, A., Afzal, S. (2014).Arduino web server for efficiently control andmonitoring of solar power system. Int. J. Comput.Eng. Appl. 8(1), pp. 148–157.
  17. Amirgaliyev, Y., Kunelbayev, M.. Wójcik, W.,Amirgaliyev, B., Kalizhanova, A., Auelbekov, O.,Kataev, N., Kozbakova, A. (2018). Calculation andselection of flat-plate solar collector geometricparameters with thermosiphon circulation. Journalof Ecological Engineering, Volume 19, Issue 6,pp. 176-181.
  18. Padilha, A. (1983). Estocagem por estratificac ̧a ̃ote ́rmica de lı ́quido em reservato ́rio. Dissertac ̧a ̃o de Mestrado. Universidade Federal do Rio deJaneiro, Rio de Janeiro.
  19. Fabry, C. (1962). Ele ́ments de thermodynamique.11th edn., vol. 1, 1 vols. Paris: Armand Colin.
  20. Amirgaliyev, Y.N., Kunelbayev, M., Wójcik, W.,(...), Kozbakova, A.K., Irzhanova, A.A. (2018).Solar-driven resources of the Republic ofKazakhstan. News of the National Academy ofSciences of the Republic of Kazakhstan, Series ofGeology and Technical Sciences, 3(430), pp. 18-27.
  21. Amirgaliyev, Y., Kunelbayev, M., Wójcik, W., (...),Kataev, N., Kozbakova, A. (2018). Calculation andselection of flat-plate solar collector geometricparameters with thermosiphon circulation. Journalof Ecological Engineering, 19(6), pp. 176-181.

View full text (PDF)